AWG ERIF Test Case 16: *MAT_264 / *MAT_TABULATED_JOHNSON_COOK_ORTHO_PLASTICITY
Image: Test Case 16 Set 1
Description: This Test Case compares *MAT_264 and *MAT_224_GYS in the isotropic limit, but with different yield stresses in tension, compression, and shear for the five load conditions bi-axial tension, uni-axial tension, pure shear, uni-axial compression, and bi-axial compression. The purpose of this test case is to verify that *MAT_264 gives the same results as *MAT_224_GYS for an isotropic material.
Status: Accepted and currently part of the AWG Test Suite
Classification: Verification
Input Deck: Test Case 16 Input
Keywords: *MAT_264
*MAT_224_GYS
Units: mm (length), ms (time), kg (mass), kn (force), GPa (stress), degrees K (temperature)
Model Data: 88 nodes / 10 solid elements / 2 materials / 10 parts
Run Time: approx. total CPU time = 5 seconds (Intel® Xeon® CPU E7- 8837 @ 2.67GHz / MPP / 1 cpu's)
Earliest Version: LS-DYNA® R10.0
Test Case Details and Results: Test Case 16, Documentation and Results for LS-DYNA R14.1.1-4-gaf1eb871e8
Test Case 16, Documentation and Results for LS-DYNA R12.2-223-gcef54b474c
Test Case 16, Documentation and Results for LS-DYNA R14.1-7-gea5f83301c
Test Case 16, Documentation and Results for LS-DYNA R12.2 Revision 1-g2dd504fe3d
Test Case 16, Documentation and Results for LS-DYNA R14.0 Revision 461-gee93a457ac
Test Case 16, Documentation and Results for LS-DYNA R13.1 Revision 93-g6e31b592d7
Test Case 16, Documentation and Results for LS-DYNA R13.0 Revision 365-gf8a97bda2a
Test Case 16, Documentation and Results for LS-DYNA R12.1 Revision 128-g57c3366e82
Test Case 16, Documentation and Results for LS-DYNA R12.0 Revision 148708
Test Case 16, Documentation and Results for LS-DYNA R11.2 Revision 51-g7e1aee4
Test Case 16, Documentation and Results for LS-DYNA R11.1 Revision 139325
Test Case 16, Documentation and Results for LS-DYNA R11.0 Revision 130010
Test Case 16, Documentation and Results for LS-DYNA R10.1 Revision 123136
Test Case 16, Documentation and Results for LS-DYNA R10.0 Revision 116539
Bug Issues Found and Fixed: BUG 13652: Differences between SMP single and double precision for the effective stress in *MAT_264 elements, fixed in DEV-r127986, R11-r127987, and R10-r128043.



last modified on Tuesday July 9, 2024 14:07:12 PDT