Image: |
|
Description: | This Test Case compares *MAT_264 and *MAT_224_GYS in the isotropic limit, but with different yield stresses in tension, compression, and shear for the five load conditions bi-axial tension, uni-axial tension, pure shear, uni-axial compression, and bi-axial compression. The purpose of this test case is to verify that *MAT_264 gives the same results as *MAT_224_GYS for an isotropic material.
|
Status: | Accepted and currently part of the AWG Test Suite
|
Classification: | Verification
|
Input Deck: | Test Case 16 Input
|
Keywords: | *MAT_264
|
| *MAT_224_GYS
|
Units: | mm (length), ms (time), kg (mass), kn (force), GPa (stress), degrees K (temperature)
|
Model Data: | 88 nodes / 10 solid elements / 2 materials / 10 parts
|
Run Time: | approx. total CPU time = 5 seconds (Intel® Xeon® CPU E7- 8837 @ 2.67GHz / MPP / 1 cpu's)
|
Earliest Version: | LS-DYNA® R10.0
|
Test Case Details and Results: | Test Case 16, Documentation and Results for LS-DYNA R14.1.1-4-gaf1eb871e8
|
| Test Case 16, Documentation and Results for LS-DYNA R12.2-223-gcef54b474c
|
| Test Case 16, Documentation and Results for LS-DYNA R14.1-7-gea5f83301c
|
| Test Case 16, Documentation and Results for LS-DYNA R12.2 Revision 1-g2dd504fe3d
|
| Test Case 16, Documentation and Results for LS-DYNA R14.0 Revision 461-gee93a457ac
|
| Test Case 16, Documentation and Results for LS-DYNA R13.1 Revision 93-g6e31b592d7
|
| Test Case 16, Documentation and Results for LS-DYNA R13.0 Revision 365-gf8a97bda2a
|
| Test Case 16, Documentation and Results for LS-DYNA R12.1 Revision 128-g57c3366e82
|
| Test Case 16, Documentation and Results for LS-DYNA R12.0 Revision 148708
|
| Test Case 16, Documentation and Results for LS-DYNA R11.2 Revision 51-g7e1aee4
|
| Test Case 16, Documentation and Results for LS-DYNA R11.1 Revision 139325
|
| Test Case 16, Documentation and Results for LS-DYNA R11.0 Revision 130010
|
| Test Case 16, Documentation and Results for LS-DYNA R10.1 Revision 123136
|
| Test Case 16, Documentation and Results for LS-DYNA R10.0 Revision 116539
|
Bug Issues Found and Fixed: | BUG 13652: Differences between SMP single and double precision for the effective stress in *MAT_264 elements, fixed in DEV-r127986, R11-r127987, and R10-r128043.
|